Chapter 5

Installing the Peripherals

5-4

Figure 5.2

Set Operating Voltage and Address on a 209Mbyte or 418Mbyte

Industrial Disk

1. Locate the operating voltage switch.

2. Set the switch to either 230V or 115V.

The switch is factory set at 230V ac.

3. Set ID4 address to 0.

ID5 address to 0 and 1.

Important: Set each disk to a unique address.

5710ĆID4

0

18537

5710ĆID5

0
1

or

ATTENTION: The 5710-ID6 has SCSI bus address preset to 0
and 1. The 5710-ID7 has SCSI bus address preset to 2 and 3.
These values are not configurable.

Wire an OutĆofĆTemperature Warning Device

If you are not going to wire this device, you can skip this section. Check
the disk information from your system designer. It should tell you if you
are going to make this connection and if so, what device you are going
to connect.

Important: For industrial disk cat. no. 5730-ID3, this function is not
available on early revisions with part numbers 532029301 and 532029302.

If the disk’s external environment temperature falls below 0

°

C or exceeds

60

°

C and remains so, you have no less than 9 minutes to orderly shut down

the system. After 9 minutes, the disk shuts itself down and data may
be lost.