Rockwell Automation 5000,D50006.2.10 PI INSTALLATION MANUAL User Manual

Page 152

Advertising
background image

Chapter 12

Configuring Hardware for the MicroVAX

Information Processors

12-14

VSmsv_RES_Succ

>>>

then the disk is in good operating condition. Go to the Setting
Defaults section, to continue starting up the MicroVax Information
Processor hardware.

If you see a display similar to this:

VSmsv_STS_NBBcnt = X

and

X

is Greater than 50, then replace the disk.

Format Disk

To format a disk, follow the procedure below.

Important: The formatting procedure erases the entire disk. If you have
information on the disk that you want to save, copy it to another disk
before beginning this procedure.

1.

Be sure you are at the console prompt, then enter:

TEST 70

2.

You see:

KA630–IN RDRXfmt

VSfmt_QUE_unitno (0–2)?

Enter: 0 to format Disk 0 or 1 to format Disk 1.

If you see:

VSfmt_STS–Siz

then everything is working normally.

If you see:

VSfmt_RES–ERR #1

then you typed an incorrect number. Start over by entering

TEST 70

again. If the message continues to appear, call your service
representative.

Advertising