Rockwell Automation 5000,D50006.2.10 PI INSTALLATION MANUAL User Manual
Page 149

Chapter 12
Configuring Hardware for the MicroVAX
Information Processors
12-11
The MicroVAX Information Processor tests each device individually
during the first pass and displays error codes for each device tested. Then
it tests all the devices together and displays another set of error codes.
This procedure should take about 11 minutes.
To run the system exerciser:
1. Be sure you are at the console prompt.
2. Enter :
TEST 0
3. The system begins testing individual devices. Watch the screen for
the first set of error codes.
Important: The following is only a sample test 0.
KA42-IN V2.1 01 CU
C 0080 DZ 0000.001 14 1005 0 00:00:35
B 0010 MEM 0010.0001 5 0 00:01:12
7 0090 SCSI-A 6000.0001 22 0002 0 00:02:23
3200.0001
6 00A0 SCSI-B 6000.0001 15 0002 0 00:02:56
2200.0001
3200.0001
7200.0001
2 00A1 BPI 0000.0001 1 0 00:03:06
1 00C0 NI 0000.0001 9 0 00:04:01
4. The system then tests the devices together. When testing is complete,
the final error codes are displayed. Use
the results.
Important: Before you replace any hardware, be sure to check the
cabling and wiring. Also make sure the modules, disk drives, and
program loader are properly connected and powered-up.