Rockwell Automation 5000,D50006.2.10 PI INSTALLATION MANUAL User Manual

Page 85

Advertising
background image

Chapter 6

Installing the Vision Components

6-4

Color Monitor

To connect the color monitor, follow the steps below.

1. Connect each of the four colorĆcoded cables into its

port on the monitor (connect the white cable to the port

labeled SYNC).

2. Route the cables to the user interface.

3. Connect the other end of each cable into

corresponding port on the user interface.

BLUE

GREEN

RED

POWER LIGHT

PEN

SYNC

INPUT

16776

Color monitor

User interface

Black and White Monitor

To connect the black and white monitor, follow the steps below:

VID EO

IN

1. Plug the cable into the monitor's port

labeled VIDEO IN.

2. Route the cable to the user interface.

3. Plug the other end of the cable into the

user interface's port labeled GREEN.

16901

BLUE

GREEN

RED

POWER LIGHT

PEN

SYNC

INPUT

Black and white monitor

User interface