Connect to remote i/o link, What to do next, Connect to remote i/o link what to do next – Rockwell Automation 5000,D50006.2.10 PI INSTALLATION MANUAL User Manual

Page 88

Advertising
background image

Chapter 6

Installing the Vision Components

6-7

If you have to make this connection, use the steps below to attach the cable
to the module using Belden 9463 cable.

1. Remove the male connector for the port labeled RIO

and wire it as shown below:

Shield

Blue2

Clear 1

2. Plug the wired connector into the processor's

female connector labeled RIO.

3. Route the cable to the adapter as shown in the

wiring documentation.

4. Attach the other end of the cable to the adapter.

16781

After completing the installation of your vision components,

If you are:

Go to chapter:

Installing I/O

7

Not installing I/O

8

Connect to Remote I/O Link

What to do Next