Chapter 12

Configuring Hardware for the MicroVAX

Information Processors

12-4

See Power-up Self-test
To see the power-up self-test display, power up the system.

1.

Make sure the terminal is set up and connected to port 3 on the
distribution panel.

2.

Power up the MicroVAX Information Processor and the terminal. If
they are already on, reboot them by turning the module’s keyswitch to
Boot. You should see a similar display like this one:

KA42-IN V1.0

F_..E...D...C...B...A...9...8...7...6...5...4_..3_..2...1...

There should be a

_

after the

F

,

4

, and

3

.

If you see:

It means:

...

device tested successfully or has a soft error.

?..

device has a hard error. To find out more information, use

TEST 50 to see the system configuration display.

_..

device not installed or not tested.

*..

device installed but its ROM is destroyed.