Check peripherals, 11ć9 – Rockwell Automation 5000,D50006.2.10 PI INSTALLATION MANUAL User Manual

Page 136

Advertising
background image

Chapter 11

Checking the Hardware

11-9

To test the industrial disk (5710-ID4, -ID5, -ID6, -ID7), follow the
steps below:

1.

Apply power to the industrial disk.

2.

Check the indicators.

The indicator labeled:

Should be:

If it is not:

CABLE PRESENT

ON (If connected to the MicroVAX

Information Processor module)

make sure the cable is secure at the industrial disk

and the MicroVAX Information Processor.

DRIVE #1 DATA ACCESS

OFF

the MicroVAX Information Processor is accessing

the disk. This is normal.

DRIVE #2 DATA ACCESS

2

OFF

the MicroVAX Information Processor is accessing

the disk. This is normal.

DISK POWER

ON

make sure the power connection is correct

and secure.

PROCESSOR FAULT

OFF

cycle power. If it does not go OFF, the processor

that controls the disk drive's environment has

faulted. Call support services.

HEATER ON

1

OFF

wait a few minutes. It should go OFF (if performing

a cold start, this LED may stay ON for a half hour).

COOLER ON

1

OFF

wait a few minutes. It should go OFF (if performing

a hot start, this LED may stay ON for up to an hour

and a half).

1

Either the HEATER ON or COOLER ON LED could be on at startup (depending on the internal temperature of the disk). If both LEDs are ON, call support services.

2

The DRIVE #2 DATA ACCESS indicator is only present on 5710ĆID5; it is not present on 5710ĆID4. DRIVE #1 data access and DRIVE #2 data access are not

present at all for 5710ĆID6 and ĆID7.

Check Peripherals

Advertising