Chapter 6

Installing the Vision Components

6-6

You can connect up to 16 I/O modules to the I/O board (1771-JMB).
Check your vision documentation to see which connections you have to
make and follow the steps below.

1.

Gather the I/O modules you are to install.

0

1

2

3

4

5

6

7

8

9

10

11

12

14

0

15

49

13

11

1

KEY

SLOT

13

2 connectors for

trigger inputs

14 connectors for

general outputs

16899

2.

Attach each I/O module to the I/O board.

(

1. Push the I/O module into its

connectors (see your system

designer vision information).

2. Using a phillips screwdriver,

secure the connection by

tightening the module's screw.

16900

DIMENSIONS

(MILLIMETERS)

INCHES

3.

Wire the terminal strip as indicated in your system designer vision
documentation.

Connect the I/O Board