Verify and format disk (for 5730-cpu1), 12ć12 – Rockwell Automation 5000,D50006.2.10 PI INSTALLATION MANUAL User Manual

Page 150

Advertising
background image

Chapter 12

Configuring Hardware for the MicroVAX

Information Processors

12-12

Table 12.D

System Exerciser Display Codes

If this device:

Displays this system exerciser

error code:

And:

Then:

DZ

0000.0001 or 0000.4001

--

the device is good.

<> 0000.0001 or <>0000.4001

--

replace the module.

MEM

XXXX.0001

XXXX is number of pages of

memory tested

the device is good.

<>XXXX.0001

--

replace the module.

HDC

1

XXXX.0001

no hard drives are connected the module is good.

<>XXXX.0001

no hard drives are connected replace the module

<>XXXX.0001

one or two drives are

connected and code

XXXX.0001 is displayed when

no hard drives are connected

one or both of the hard drives needs to be

replaced. Test each configured to module

separately to determine which (or both)

is bad.

TPC

1

8000.0001

the program loader

is connected

the program loader and module are good.

<>8000.0001

the program loader

is connected

replace the program loader.

XXXX.XXXX

a program loader is not

connected

the module is good.

SCSIĆA

2

XXXX.0001

--

the device is good.

<>XXXX.0001

--

replace the module.

SCSIĆB

2

XXXX.0001

--

the device is good.

<>XXXX.0001

--

replace the module.

BPI

2

0000.0001

--

the dual port is good.

<>0000.0001

--

replace the module.

NI

0000.0001

--

the Ethernet port and cable are good.

<>0000.0001

--

replace the module.

1

MicroVAX Information Processor (cat. no. 5730ĆCPU1) only.

2

MicroVAX Information Processor EP or EE (cat. nos. 5731ĆCPU1, ĆCPU2) only.

We recommend that you verify the industrial disk in your configuration
before you format or begin installing software on it. The verification
procedure will tell you if:

the disk has been formatted
the disk is in good condition

Verify and Format Disk

(for 5730ĆCPU1)