Chapter 12

Configuring Hardware for the MicroVAX

Information Processors

12-8

2.

Use the error codes in Table 12.C to trouble-shoot the MicroVAX
Information Processor’s hardware. For more information, see the
VAXstation

3100 and MicroVAX 3100 Maintenance Guide or call

your service representative.

Important: Before you replace any hardware, be sure to check the
cabling and wiring. Also make sure the modules, disk drives, and
program loader are properly connected and powered-up.

Table 12.C

Hardware SelfĆtest Error Codes

If this device:

Displays this selfĆtest

error code:

Then:

CLK

0000.0001

the device is good.

0000.0005

set the system time.

<>0000.0001

replace the module.

NVR

0000.0001

the device is good.

0000.0005

set system time after replacing the module battery.

<>0000.0001

replace the module.

DZ

0000.0001 or 0000.4001

the device is good.

<> 0000.0001 or

<>0000.4001

replace the module.

MEM

00XX.0001 (and

X=number of Mbytes

of memory)

the device is good.

<>00XX.0001

replace the module.

MM

0000.0001

the device is good.

<> 0000.0001

replace the module.

FP

0000.0001

the device is good.

<> 0000.0001

replace the module.

IT

0000.0001

the device is good.

<> 0000.0001

replace the module.