Switch settings – Rockwell Automation 5000,D50006.2.10 PI INSTALLATION MANUAL User Manual
Page 182
Advertising
![background image](/manuals/580790/182/background.png)
Cable Connections for the RM and KA Module
Appendix C
C-2
Figure C.1 shows an example of how to configure the switch settings for a
1770-KF2 or a 1785-KE communication interface module.
Figure C.1
Example switch settings for 1770ĆKF2 or 1785ĆKE
SWĆ5
57600
bit/s
SWĆ6
9600
bit/s
SWĆ7
DH+
SWĆ8
RSĆ232
SWĆ2
Address
SWĆ3
Address
SWĆ4
Address
SWĆ1
Full duplex
BCC None
(Parity)
SWĆ8
SWĆ1
SWĆ2
SWĆ3
SWĆ4
SWĆ5
SWĆ6
SWĆ7
Off
(0)
On
(1)
Side view
17091
Switch:
Function:
SWĆ1
asynchronous link features
SWĆ2, SWĆ3, SWĆ4
station address
SWĆ5
DH baud rate
SWĆ6
asynchronous link baud rate
SWĆ7
DH+ network
SWĆ8
RSĆ232ĆC or RSĆ422 selection
For more information about the different possible switch settings, see the
documentation for your communication interface module.
Switch Settings