Internal 150-ohm termination resistors for rs2, Figure 4.1, Table 4.e – Rockwell Automation 5000,D50006.2.10 PI INSTALLATION MANUAL User Manual

Page 54: To configure your termination resistors for rs2, Install the rs

Advertising
background image

Chapter 4

Installing the Modules

4-16

Table 4.E

Configure Termination Resistors for the RS2

If the transmission rate is:

And the scanner is physically located: Then put the internal 150ĆOhm

terminationĆresistor jumper in the:

57.6k bit/s or 115k bit/s

middle of remote I/O link

out position

end of remote I/O link

in position

230k bit/s

middle of remote I/O link

out position

end of remote I/O link

out position, and attach 82ĆOhm termination

resistor between pins 2 and 3

Figure 4.1

RS2 Internal 150ĆOhm Termination Resistors

(Front)

Module

Memory module

RS2 (internal 150ĆOhm termination resistor)

17085

Termination

Resistor

CH JMPR

IN

OUT

1

E1

3 2 1

3 2 1

2

E2

3 2 1

3 2 1

Install the RS

Install the module as shown in appendix A.

Advertising