Chapter 4

Installing the Modules

4-7

3.

Connect the 5120-CP2 cable to the fan chassis, the power supply
and a 24V external power supply.

5120ĆCP2

a. Connect the spade lugs to

an external 24V power supply.

b. Connect the rightĆangle

connector of the 5120ĆCP2

cable to the port labeled FAN

CHASSIS on the power supply.

c. Route the cable away from

the Interlock Relay and Line

Voltage connectors.

d. Connect the straight end of

the cable to the port labeled

FAN STATUS CABLE on the

fan chassis.

Connect triple red to +.

Connect triple

black to -.

Connect single red

to + sense or +.

Connect single black

to - sense or -.

19786

4.

Connect the 5120-CP3 cable to a 24V external power supply.

Connect triple red to +.

Connect triple

black to -.

Connect single red

to + sense or +.

Connect single black

to - sense or -.

5120ĆCP3

a. Connect the spade lugs

to an external 24V power

supply.

b. Connect the rightĆangle

connector of the 5120ĆCP3

cable to the port labled

FAN CHASSIS on the

power supply.

c. Route the cable away

from the Interlock Relay

and Line Voltage

connectors.

19787

Connect to Interlock Relay

See chapter 9 to connect the interlock relay.

Connect to Line Voltage

See chapter 10 to connect ac power.