Connect the fan assembly/external power source – Rockwell Automation 5000,D50006.2.10 PI INSTALLATION MANUAL User Manual

Page 44

Advertising
background image

Chapter 4

Installing the Modules

4-6

Connect the Fan Assembly/External Power Source

If you have a fan assembly or are connecting the power supply to an
external power source, make this connection. If you don’t have to make
this connection, go to the next section. To make this connection, follow
the steps below.

1. Determine which fan assembly and/or power source connections you

are making.

If you have this configuration:

Make this connection:

With this cable:

Go to this step:

PI chassis with MicroVAX Information Processor

and no vision processor

power supply to fan assembly

cat no. 5120ĆCP1

2.

PI chassis with a MicroVAX Information Processor

and at least one vision processor

power supply to fan assembly and

external power source

cat no. 5120ĆCP2

3.

PI chassis with more than two vision processors

At least one vision processor, PLCĆ5/250

controller and no MicroVAX

Information Processor

power supply to external power source

cat no. 5120ĆCP3

4.

2. Connect the 5120-CP1 cable to the fan chassis and the power supply.

a. Gather the fan status cable that

came with the fan assembly.

b. Connect the rightĆangle connector

of the fan status cable to the port

labeled FAN CHASSIS on the

power supply.

c. Route the fan status cable away

from the Interlock Relay and Line

Voltage connectors.

d. Connect the straight end of the

cable to the port labeled FAN

STATUS CABLE on the fan chassis.

5120ĆCP1

19785

Advertising