Rockwell Automation 5000,D50006.2.10 PI INSTALLATION MANUAL User Manual

Page 147

Advertising
background image

Chapter 12

Configuring Hardware for the MicroVAX

Information Processors

12-9

If this device:

Then:

Displays this selfĆtest

error code:

HDC

1

7770.0001

0 disks are connected to the module and the device is good.

7710.0001

1 disk is connected to the module and the device is good (DUA1).

7110.0001

2 disks are connected to the module and the device is good (DUA0).

7ABC.WXYZ

where:

A = drive DUA1

B = drive DUA0

X = control status for DUA1

Y = control status for DUA0

if either X or Y is:

2, 4, 6, 8, A, C, E

there is a fatal error. Replace disk or call AĆB representative.

if either X or Y is:

5,F

check to see if disk is formatted. If the disk is formatted, it indicates a

controller error. Call AĆB representative.

if either X or Y is:

3,9

it is a warning. Try again.

7777.7777

check that drive has power and cables are properly connected,

replace the specified disk.

TPC

1

0000.0001

the tape controller and the program loader are good.

0000.4001

the tape controller is good and the program loader is not connected.

WXYZ.0001

and WX=YZ

and WX<>YZ

then the module is communicating with the program loader.

disconnect the program loader cable (turn off program loader, unplug

data cable, then unplug power cable. See Appendix B for more

information) and run the selfĆtest again (TEST 6).

if you don't see 0000.4001, replace the cable and run the

selfĆtest again.

if you see 0000.4001, reconnect the cable, power down the

system and power up the system again. Run the selfĆtest again.

You should then see 1212.0001. If you don't see 1212.0001, run

the system exerciser.

WXYZ.ABCD

and CD>01

replace the module.

and B is:

1

2

3

check that program loader has power and cables are properly

connected then:

replace the module.

replace the program loader.

replace both.

and A is:

1

check that program loader has power and cables are properly

connected then:

retest TPC.

3

retest the program loader.

4

replace the module and the program loader.

5

the controller doesn't recognize the program loader. Follow the

procedure above for when WX<>YZ.

6

retest TPC and the program loader. Follow the procedure above for

when WX<>YZ.

7

replace the program loader.

1

MicroVAX Information Processor (cat. no. 5730ĆCPU1) only.