Chapter 7

Installing 1771 I/O

7-10

On the 1771-AM1, -AM2 I/O chassis with integral power supply and
adapter set the switches as shown in Figure 7.5.

Figure 7.5

Switch Settings on the I/O Chassis with Integral Power Supply and Adapter

(1771ĆAM1,ĆAM2)

Last State

On

Off

Outputs of this I/O chassis remain in their last state

when a fault is detected by this I/O adapter.

detected by this I/O adapter.

Processor Restart Lockout

On

Off

The I/O chassis can be

restarted from the processor

The processor is locked out

from restarting the I/O

chassis after a fault.

Data Transmission Rate

On
Off

57.6k bit/s (10,000 ft. max.)
115.2k bit/s (5,000 ft. max.)

SW1

SW2

Always

On

Always

On

Output of this I/O chassis are turned Off when a fault is

I/O Rack

Number

on

on

off

off

Starting

I/O Group

on

off

on

off

0

2

4

6

Addressing

1/2Ćslot

On

1Ćslot (select this always for 1771ĆAM1)

Off

12211ĆI

12

3

4

5

6

7

8

Off (away from board)

On (toward board)

91

0

1

1
1

2

1

234

5

6

Set 1771ĆAM1, ĆAM2 I/O

Chassis/Adapter Switches