Chapter 2

Mounting the Components

2-7

4.

Return the panel to its enclosure:

a.

Scrape paint and other nonconductive finishes from the shoulder
studs on the back wall of the enclosure. Scrape clear an area at
least as large as the washer to be used.

b.

Attach the panel to the back wall of the enclosure as
shown here:

Panel

Nut

Star washer

Shoulder bolt on back

wall of enclosure

Back wall of

enclosure

13871

5.

Repeat this procedure for each component you mount:

a.

Position the component on the screws you have prepared for it
on the panel.

b.

Attach the component to the panel as shown below. Do not
tighten the nuts yet (you will tighten the nuts after you have
completed grounding the component).

Mounting bracket

#10Ć32 screw

Star

washer

16732

Flat

washer

Bolt

Flat

washer

Scrape paint

Tapped hole

Back panel

If the mounting bracket is coated with

a nonĆconductive material (anodized,

painted, etc.), scrape the material

around the mounting hole.

Advertising