Chapter 4

Installing the Modules

4-21

Set the Module Address

Follow the steps below to set the module address.

1

1. Locate the pushwheel on the front panel

of the CVIM module.

2. Set the pushwheel as indicated on

Worksheet 2.2.

Setting the pushwheel:

To: Push the:

decrease the number

increase the number

top button

bottom button

16753

There are other connections to make to the vision processor modules. To
continue installing the vision components, see chapter 6.

Important: If you have a RM with firmware revision A04 or earlier and
you’re replacing a MicroVAX Processor, go to the section “Replace a
MicroVAX Processor” on page

4-24

.

To install the MicroVAX Information Processor, use the appropriate
worksheet as a guide and complete the following:

install the processor in the chassis
install the battery
set the keyswitch
connect Ethernet and make other connections to the module
replace the module (if applicable)

Install the Processor

See appendix A to install the processor in the chassis.

MicroVAX Information

Processors