Chapter 11

Checking the Hardware

11-10

To test the industrial disk (5710-ID3), follow the steps below:

1.

Apply power to the industrial disk.

2.

Check the indicators.

The indicator labeled:

Should be:

If it is not:

CABLE PRESENT

ON (If connected to the MicroVAX

Information Processor module)

make sure the cable is secure at the industrial disk

and the MicroVAX Information Processor.

DATA ACCESS

OFF

the MicroVAX Information Processor is accessing

the disk. This is normal.

DISK POWER OK

ON

make sure the power connection is correct

and secure.

PROCESSOR FAULT

OFF

cycle power. If it does not go OFF, the processor

that controls the disk drive's environment has

faulted. Call support services.

ENV POWER OK

ON

disconnect power from the disk and check the

fuses on the disk's power supply. If necessary,

replace the 250V, 5 amp and/or 7 amp

slowblow fuses.

HEATER ON

1

OFF

wait a few minutes. It should go OFF (if performing

a cold start, this LED may stay ON for a half hour).

COOLER ON

1

OFF

wait a few minutes. It should go OFF (if performing

a hot start, this LED may stay ON for a half hour).

1

Either the HEATER ON or COOLER ON LED could be on at startup (depending on the internal temperature of the disk). If both LEDs are ON, call support services.

To test other peripherals you have installed, follow the steps below:

1.

Apply power to each peripheral and make sure the power indicators
are on.

2.

If the power indicators are off, remove power and make sure the
connections are correct and secure. Re-apply power and re-check
the indicators.