Chapter 5

Installing the Peripherals

5-9

To connect the 4-port distribution panel, follow the steps below.

1.

Route the cable from the back of the distribution panel to the
information processor.

2.

Using the following pin-outs table to construct a cable for the device
that will connect to the panel.

Port 0

Port 1

Port 2

Port 3

Pin

Signal

Pin

Signal

Pin

Signal

Pin

Signal

2

TXD0

2

TXD1

2

TXD2

2

TXD3

3

RXD0

3

RXD1

3

RXD2

3

RXD3

7

SIG GND

7

SIG GND

4

RTS2

1

7

SIG GND

5

CTS2

1

6

DSR2

7

SIG GND

8

DCD2

1

20

DTR2

22

RI

1

1

5731ĆCPU1 and 5731ĆCPU2 do not support line signals.

3.

Connect the cable to the MicroVAX Information Processor’s port
labeled Comm Port (5731-CPU-1, CPU-2) or Serial CH A
(5730-CPU1).

4.

Connect the device to the distribution panel.

a.

Attach one end of the cable you made to the appropriate
connector on the distribution panel (port 3 is the console port).

b.

Attach the other end of the cable to the device.

The program loader connects to the MicroVAX Information Processor.
Connect the program loader before you boot the system. To connect the
program loader, follow the steps below.

1.

Plug in the program loader.

2.

Run the cable with the 50-pin, D-shell connector from the program
loader to the MicroVAX Information Processor.

3.

Connect the 50-pin, D-shell connector to the port labeled LOADER
on the MicroVAX Information Processor.

For more information on the program loader, see the Program Loader
Installation Data
(5000-2.93).

Install the 4ĆPort

Distribution Panel

Install the Program Loader