1.10 What is new in tiamo 2.4?

■■■■■■■■■■■■■■■■■■■■■■

16

■■■■■■■■

tiamo 2.4 (for Process Analysis)

If a new stepper motor was created in the STEPPING MOTOR com-
mand on the Stepping motors tab or the properties of an existing
one viewed, then the title of the dialog window was Method varia-
ble -
(instead of STEPPING MOTOR #, e.g. similar to the DIGITAL
OUT
command) (the error was already eliminated in tiamo 2.3, Patch
1).

If a method containing the KFC command was imported from tiamo
1.x into tiamo 2.x, an error message was displayed during the run. The
user had to select the sensor again and save the method in order to
make it runnable again.

The maximum run time was not correctly observed in the commands
LOOP, DIGITAL IN and ANALOG IN.

In the online help, the input range for the maximum run time was not
correct in the DIGITAL IN command on the Stop criteria tab.

The formula for filling rate 2 for tandem dosing has been corrected in
the online help.

The command variables beginning with RS, CV or GV were not cor-
rectly displayed for the CALC command in the formula editor in the
variable tree.

If not defined was selected as device name, then the device type was
not indicated in the method parameters in the method report and in
the Fixed report.

If the method parameter report of a method containing the release
commands RLS DOS and/or RLS DEV was output in the program part
Method or Database, the corresponding fields were not output in
the generated PDF file.

Configuration program part

If a barcode reader and a balance were included first in the device con-
figuration for the light version, then it was no longer possible to
include Metrohm devices (the error was already eliminated in tiamo
2.3, Patch 1).

The incorrect text designation for the colorimetric sensors was used
(Sensor instead of Colorimetric sensor) in the user administration
under "Access rights for group 'Group designation', Configuration,
Functions" (the error was already eliminated in tiamo 2.3, Patch 1).

The online help for the Limit values for colorimetric sensor –
'Name of the colorimetric sensor'
dialog window was missing (the
error was already eliminated in tiamo 2.3, Patch 1).

After a pH calibration, the calibration date is also entered on the Cali-
bration data
tab with the sensors, among other things. If, after a suc-
cessful calibration, the intelligent sensor was deleted from the configu-
ration and then included again, then the Date ELT could be seen in
the Calibration date field (the error was already eliminated in tiamo
2.3, Patch 1).