118

System Information and Errors, Leica mojoXact Plus

Displaying correc-
tion source status,
step-by-step

To view the status of the configured correction source, carry out the following steps:

Reference Latency - The time in seconds since the last packet of usable reference

data has been received by the mojoXact Plus. The ideal range
is between 0.1 and 3.0 seconds. The reference latency is

displayed as 60.00s when using GL1DE

TM

or there is no refer-

ence data.

Receiving Data -

A

indicates that the mojoXact Plus is receiving data from

the base station and a

indicates that it is not.

Distance -

The distance between the base station and the mojoXact Plus.

Packets Passed -

The number of good packets of reference data received by the
mojoXact Plus. This value should increase by one (1) every one
or two seconds.

SW Version -

The current software version installed on the base station.

Serial Number -

The device and serial number of the base station.

Low Battery -

A

indicates that there is currently a low battery warning

message on the base station, and a

indicates that there

is not.

External Power -

A

indicates that the base station is using an external

power source, and a

indicates that it is not.

1. On the main navigation screen, select the Service button.

The Service menu appears.

2. Select the Correction Source Information button.

The Correction Source Status screen appears.