System Information and Errors, Leica mojoXact Plus
Displaying correc-
tion source status,
step-by-step
To view the status of the configured correction source, carry out the following steps:
Reference Latency - The time in seconds since the last packet of usable reference
data has been received by the mojoXact Plus. The ideal range
is between 0.1 and 3.0 seconds. The reference latency is
displayed as 60.00s when using GL1DE
TM
or there is no refer-
ence data.
Receiving Data -
A
indicates that the mojoXact Plus is receiving data from
the base station and a
indicates that it is not.
Distance -
The distance between the base station and the mojoXact Plus.
Packets Passed -
The number of good packets of reference data received by the
mojoXact Plus. This value should increase by one (1) every one
or two seconds.
SW Version -
The current software version installed on the base station.
Serial Number -
The device and serial number of the base station.
Low Battery -
A
indicates that there is currently a low battery warning
message on the base station, and a
indicates that there
is not.
External Power -
A
indicates that the base station is using an external
power source, and a
indicates that it is not.
1. On the main navigation screen, select the Service button.
The Service menu appears.
2. Select the Correction Source Information button.
The Correction Source Status screen appears.
3. To return to the main navigation screen, select
.
To return to the Service menu, select
.