INSTALLATION

Version 6.0

Online Environment

The S

3

software suite consists of a number of separate application programs that work together to collect,

distribute and display data from a variety of sources.

At the center of the suite is an application program called the “Data Collector and Distributor” or “DCD” for

short.

DCD

The DCD is the heart of all online operations. It handles all of the

OIS communication processes including serial communications to

attached systems, TCP/IP communication with attached systems,

communication with OPC clients, and peer-to-peer communications with

other S

3

application programs both local and remote.

The DCD can control up to ten communication ports, either individual

serial ports or TCP/IP connections.

It collects data from these ports to update the tag database in accordance

with the configurations of the individual attached systems.

Other S

3

application programs query the DCD to perform their individual

functions such as, updating the active alarm list, generating the alarm

history and daily log, and servicing remote access requests.

Installation Options

There are two installation options available depending on how the workstation is to be used. They are; Operations

and Development.

Operations Installation Selection

This installation is designed for full time Operator Interface Station (OIS)

operations where the system will be “online” around the clock and will be

used by operations personnel as a window into the safety system.

If the “Operations” selection is used for installation, the system will be

configured as a secure stand-alone OIS with tight security restrictions

installed at the lowest levels of the operating system.

The user must be logged into Windows as the “Administrator” in order to

install this option.

When the “Operations” installation is used S

3

takes complete control of

the workstation and when “Online” access to the operating system will

not be allowed. In addition, access to other application programs or

Windows functions such as “CTL-ALT-DEL”, “ALT-TAB”, etc. will not be

available.

The “Operations” installation also configures the system so that on a loss of power (or other event that causes

a system restart) the OIS will automatically return to its previous state. S

3

will automatically restart and if online

prior to the event will return online with the last valid user logged in as the current user. If not online the station

will return to the S

3

Main Screen.

ONLINE ENVIRONMENT

INSTALLATION PROCEDURE