Chapter 6: Software Interface

6–9

Physical Layer Registers

August 2014

Altera Corporation

RapidIO II MegaCore Function

User Guide

DISCOVER

[29]

RW

This device has been located by the processing element responsible for system
configuration.

1'b0 - The device has not been previously discovered

1'b1 - The device has been discovered by another processing element

This field is for software use only. Its value has no effect on hardware.

(1)

RSRV

[28:0]

RO

Reserved

29'b0

Note to

Table 6–9

:

(1) The reset value of this field is set in the RapidIO II parameter editor.

Table 6–9. Port General Control—Offset: 0x13C (Part 2 of 2)

Field

Bits

Access

Function

Default

Table 6–10. Port 0 Link Maintenance Request CSR—Offset: 0x140

Field

Bits

Access

Function

Default

RSRV

[31:3]

RO

Reserved

29'b0

COMMAND

[2:0]

RW

Command to be sent in a link-request control symbol. When a
valid value is written to this field, the RapidIO II IP core generates a
link-request

control symbol with the specified command. The IP

core does not generate a link-request control symbol when an
invalid value is written.

The following values are valid:

3’b011: reset-device

3’b100: input-status

3'b000

Table 6–11. Port 0 Link Maintenance Response CSR—Offset: 0x144

Field

Bits

Access

Function

Default

RESPONSE_VALID

[31]

RO,RC

Value is the status of the most recent link-request control symbol
this RapidIO II IP core sent on the RapidIO link. If the link-request
control symbol is a link-request input-status control symbol,
this bit, if set, indicates that the link-response control symbol has
been received and the status fields in this register are valid. If the
link-request

control symbol is a link-request reset-device

control symbol, this bit, if set, indicates that the link-request was
transmitted.

This bit automatically clears in response to a read operation.

1’b0

RSRV

[30:11] RO

Reserved

20’b0

ACKID_STATUS

[10:5]

RO

Value of the ackID_status field in the link-response control
symbol. This field holds the value of the next expected ackID. Refer to
Table 3-3 in the RapidIO Interconnect Specification v2.2 Part 6:
LP-Serial Physical Layer Specification
.

6'b0

PORT_STATUS

[4:0]

RO

Value of the port-status field in the link-response control
symbol. Refer to Table 3-6 in the RapidIO Interconnect Specification
v2.2 Part 6: LP-Serial Physical Layer Specification.

5'b0