Altera RapidIO II MegaCore Function User Manual

Page 162

Advertising
background image

6–24

Chapter 6: Software Interface

Physical Layer Registers

RapidIO II MegaCore Function

August 2014

Altera Corporation

User Guide

Connected port transmit

emphasis Tap(+1) status

[17:16]

RO

Tap(+1) status of the RapidIO link partner on the connected
lane:

2’b00: Tap(+1) not implemented.
2’b01: Tap(+1) at minimum emphasis setting.
2’b10: Tap(+1) at maximum emphasis setting.
2’b11: Tap(+1) at intermediate emphasis setting.

2’b00

Connected port

scrambling/descrambling

enabled

[15]

RO

Indicates scrambling/descrambling is enabled in the RapidIO
link partner on the connected lane.

1’b0: Scrambling/descrambling is not enabled.
1’b1: Scrambling/descrambling is enabled.

1’b0

RSRV

[14:0]

RO

Reserved.

15’h0

Table 6–18. LP-Serial Lane n Status 1—Far End Lane n Status—Offset: 0x214, 0x234, 0x254, 0x274 (Part 2 of 2)

Field Bits

Access

Function

Default

Table 6–19. LP-Serial Lane n Status 2—Lane n Interrupt Enable—Offset: 0x218, 0x238, 0x258, 0x278

Field Bits

Access

Function

Default

RSRV

[31:30]

RO

Reserved.

2b0

Process CMD

automatically

[29]

RO

When set, enables automatic processing of CS field values received in
the IDLE2 sequence. The RapidIO II IP core does not yet implement
this feature.

1’b0

RSRV

[28:0]

RO

Reserved.

29’h0

Table 6–20. LP-Serial Lane n Status 3—Received CS Field Commands—Offset: 0x21C, 0x23C, 0x25C, 0x27C

Field Bits

Access

Function

Default

CMD changed

[31]

RW1C

A changed cmd value in the CS field (received cmd value is different from
the previously received value).

1’b0

CMD

[30]

RO

cmd value of most recently received CS field.

1’b0

RSRV

[29]

RO

Reserved.

1’b0

Data

scrambling

enabled

[28]

RO

Value received most recently from the far end.

1’b0

Lane number

in port

[27:23]

RO

x of CS field’s Dx.y value. Should match n. This field is updated with each
received CS field.

5’h00

Active port

width

[22:20]

RO

y of CS frame’s Dx.y value. This register field is updated with each
received CS field.

3’b000

RSRV

[19:8]

RO

Reserved.

12’h000

Tap(–1)

Command

[7:6]

RO

Value of this field in the most recently received CS field.

2’b00

Tap(+1)

Command

[5:4]

RO

2’b00

Reset

emphasis

[3]

RO

1’b0

Preset

emphasis

[2]

RO

1’b0

RSRV

[1:0]

RO

Reserved.

2’b00

Advertising