3–12

Chapter 3: Parameter Settings

Error Management Registers Settings

RapidIO II MegaCore Function

August 2014

Altera Corporation

User Guide

If you do not instantiate the Error Management Extension registers (refer to

“Error

Management Registers Settings” on page 3–12

), this parameter determines the

value of the EF_PTR field of the LP-Serial Lane Extended Features Block Header
register at offset 0x200 (

Table 6–16 on page 6–21

).

If you instantiate the Error Management Extension registers in your RapidIO II IP
core variation, this parameter determines the value of the EF_PTR field of the Error
Management Extensions Block Header

register at offset 0x300 (

Table 6–66 on

page 6–43

).

1

This parameter does not affect the Assembly Information CAR. The
ExtendedFeaturesPtr

in the Assembly Information CAR is set to the value of 0x100,

which is the offset for the LP-Serial Extended Features block (refer to

Table 6–2 on

page 6–2

).

Error Management Registers Settings

The Error Management Registers tab lists a single parameter, Enable error
management extension registers

.

If you turn on Enable error management extension registers, your RapidIO II IP core
instantiates the Error Management Extensions register block defined in the RapidIO
Interconnect Specification Part 8: Error Management Extensions Specification
.

The RapidIO II IP core instantiates these registers at register block offset 0x300. If you
do not instantiate these registers, you can specify user-defined registers at offset
0x300.

The RapidIO II IP core Error Management registers are described in

“Error

Management Registers” on page 6–42

.

Advertising