Test pattern generator parameter settings, Test pattern generator parameter settings -4 – Altera Video and Image Processing Suite User Manual

Page 246

Advertising
background image

}
}

Test Pattern Generator Parameter Settings

Table 19-2: Test Pattern Generator Parameter Settings

Parameter

Value

Description

Run-time control of image size

On or Off

Turn on to enable run-time control of the

image size. When turned on, the output size

parameters control the maximum values.

Maximum image width

32-2600, Default = 640 Specify the maximum width of output in

pixels.

Maximum image height

32-2600, Default = 480 Specify the maximum height of output in

pixels. This value must be the height of the

full progressive frame when producing

interlaced data.

Bits per pixel per color plane

4-20, Default = 8

Select the number of bits per pixel (per color

plane).

Color space

RGB or YCbCr

Select whether to use an RGB or YCbCr color

space.

Output format

4:4:4, 4:2:2, 4:2:0

Select the format/sampling rate format for the

output frames.

Color plane configuration

Sequence, Parallel

This function always produces three color

planes but you can select whether they are

transmitted in sequence or in parallel.

Interlacing

Progressive output

• Interlaced output

(F0 first)

• Interlaced output

(F1 first)

Specify whether to produce a progressive or

an interlaced output stream.

Pattern

• Color bars

• Uniform

background

Select the pattern for the video stream output.

Uniform values

0-255, Default = 128

When pattern is uniform background, you

can specify the individual R'G'B' or Y' Cb' Cr'

values depending on the currently selected

color space.

19-4

Test Pattern Generator Parameter Settings

UG-VIPSUITE

2015.05.04

Altera Corporation

Test Pattern Generator IP Cores

Send Feedback

Advertising