Chapter 3 Operation

POWER CON

PCON-CA/CFA

111

 

Caution: (1) The speed during pressing operation is set in Parameter No.34. Check the

9.4 List of Specifications of Connectable Actuators for the pressing

operation speed.

Do not set any value larger than the value in the list. If the speed set in the

position table is equal to or less than the pressing speed, the pressing is

performed at the setup speed.

(2) The approach start position of pressing should be located at or before the

pressing start position (coordinate 100mm or less in the above example) If

not, the moving direction varies depending on the start position to be

dangerous.

For example, pressing at coordinate larger than the pressing end position

(larger than 150mm) is performed in the direction from the current position

to the pressing end position. It would not proceed to the pressing operation

at 150mm point after positioning at 100mm point.

(3) The work is pressed after the pressing is completed. The work may moves

backward or forward. If the actuator is moved backward before the

approach position, alarm code 0DC “Pressing motion range over error”

occurs to stop the actuator. In movement of the work in the pressing

direction, PEND is turned OFF if the load current becomes lower than the

current limit (pressing (%)). Miss-pressing occurs when the actuator moves

by the pressing moving distance set in “Positioning width”.

(4) Pressing control cannot be performed with the rotary actuator.

(5) If the actuator gets pressed to the work during the approach operation, 0DC

“Pressing Operation Range Over Error” would be issued.

Positioning Completion Signal

PEND

(ControlleroPLC)

Turned OFF by

turning PEND ON

Turned on even

in miss-pressing

Start signal

ST*

(PLCoController)

Current Position No.

PE*

(ControlleroPLC)

Not turned ON for

miss-pressing

Pressing

operation

Pressing

Completion

Operation of actuator

Approach operation

Positioning be setting

of coordinate Value

Movement by

positioning

width

Stop of

pressing

Pressing start position

100mm

Pressing end position

100 + 50 = 150mm

ST*

Pressing operation

ST*

Approach operation

ST*:Start position

ST*

Pressing operation

Tensile operation

Advertising