Chapter 3 Operation

POWER CON

PCON-CA/CFA

123

[2] Features of LS signals (LS0 to 2)

The LS* signals are not complete signals for positioning commands such as those for other PIO

patterns. Despite the specified position No., the corresponding LS* signal is turned ON when

the actuator is entered into the setup value range as if the actuator were detected by a sensor

installed.

(Example) The figure below shows the position table and the position at which each of the LS

signals is turned ON. If the actuator passes any of the positioning widths in the

operation by another position number or manual operation in the servo OFF state,

the relevant LS signal is always turned ON.

Caution: LS* signal would not be output if the positioning width is set less than the

minimum resolution.



Home=0mm

70mm

150mm

LS0 is ON

0r5mm

LS1 is ON

70r10mm

LS2 is ON

150r5mm

No.

Position

[mm]

Velocity

[mm/s]

Accele-

ration

[G]

Decele-

ration

[G]

Pressing

[%]

Thresh-

old

[%]

Positioning

width

[mm]

Zone+

[mm]

Zone-

[mm]

Acceleration/

Deceleration

mode

Incre-

mental

Transported

load

Stop

mode

0

0.00

250.00

0.20

0.20

0

0

5.00

0.00

0.00

0

0

0

0

1

70.00

250.00

0.20

0.20

0

0

10.00

0.00

0.00

0

0

0

0

2

150.00

250.00

0.20

0.20

0

0

5.00

0.00

0.00

0

0

0

0