3 wiring method, Pcon-ca/cfa, Power con – IAI America PCON-CA User Manual

Page 65

Advertising
background image

Chapter 2 Wiring

POWER CON

PCON-CA/CFA

57

2.3

Wiring Method

2.3.1 Wiring Layout of Power Supply Connector

The wires of the power supply and the emergency stop circuit are to be connected to the

enclosed connector (plug).

Strip the sheath of the applicable wires for 10mm and insert them to the connector. Push a

protrusion beside the cable inlet with a small slotted screwdriver to open the inlet. After

inserting a cable, remove the screwdriver from the protrusion to fix the cable.

Power Supply Connector

Model

Remarks

Cable Side

FMC1.5/8-ST-3.5

Enclosed in standard package

Controller Side

MC1.5/8-G3.5

Pin No.

Signal

Name

Contents

Applicable cable diameter

1

EMG-

Input of emergency stop status signal KIV0.5mm

2

(AWG20)

2

0V

3

24V

Power supply input

(24V DC r10%)

(Note1)

KIV1.25mm

2

(AWG16)

4

MPO

5

MPI

Motor drive power line

KIV1.25mm

2

(AWG16)

6

S2

7

S1

Teaching pendant

Signal of emergency stop push button KIV0.5mm

2

(AWG20)

8

BKRLS

Brake release power supply input

(Note2)

(24V DC r10% 150mA)

KIV0.5mm

2

(AWG20)

(Note1) If supplying power with using a 24V DC, having it turned ON/OFF, keep the 0V

connected and have the +24V supplied/cut (cut one side only).

(Note2) The brake is forcibly released when +24V is supplied. Make the 0V in common with

the 0V of the power input.

BKRLS

S1

S2

MPI

MPO

24V

0V

EMG-

Accessory

Connector

(Plug)

When inserting wires