POWER CON

PCON-CA/CFA

140

3.3.3 Pulse Train Input Operation

[1] Command Pulse Input (PP•/PP, NP•/NP)

In the differential type, it is able to have 200kpps of pulse train input at maximum. When the

host controller possesses only the pulse output function of the open collector, it is able to input

60kpps pulse at maximum by connecting AK-04 (option).

6 types of command pulse train can be selected. Set the pulse train format in Parameter No.63

and active high/low in Parameter No.64. [Refer to 3.3.4 Settings of Basic Parameters Required

for Operation]

Caution:

(1) The directions in which the actuator moves upon receiving forward and reverse pulses

conform to the pulse count direction set in Parameter No.62.

(2) As for the forward/reverse directions, pay attention to the host controller setting or

PP•/PP and NP•/NP connections.

(3) Set the actuator acceleration/deceleration on the host controller side.

(4) The actuator acceleration/deceleration should not exceed the rated

acceleration/deceleration of the applicable actuator. [Refer to the actuator’s catalog or

the appendix in this Instruction Manual for the rated acceleration/deceleration of each

actuator.]

* The rotating direction of the motor is defined so that the counterclockwise direction

as viewed from the end of the load shaft represents the forward direction.

PP

/PP

NP

/NP

PP

/PP

NP

/NP

PP

/PP

NP

/NP

PP

/PP

NP

/NP

PP

/PP

NP

/NP

PP

/PP

NP

/NP

High

Low

High

Low

Normal Rotation

Pulse Train

Normal Rotation

Pulse Train

Reverse Rotation

Pulse Train

Reverse Rotation

Pulse Train

The normal rotation pulse train shows the motor rotation amount in normal direction, and

reverse rotation pulse train shows the motor rotation amount in reverse direction.

Pulse Train

Pulse Train

Symbol

Symbol

The command pulse shows the motor rotation amount and the command symbol shows the

rotation direction.

A/B Phase

Pulse Train

A/B Phase

Pulse Train

The A/B Phase 4-fold Pulse with the phase difference of 90° shows the commands for

the rotation amount and direction.

Command Pulse

Train Mode

Input

Terminal

In Normal Rotation

In Reverse Rotation

Negative Logic

Positive Logic