Chapter 6

Absolute Reset and

Absolute Battery

POWER CON

PCON-CA/CFA

161

6.2.4 Replacement of absolute battery

When replacing the battery, leave the power to the controller ON, remove the battery connector

and replace with a new battery.

[1]

For the Type to Attach Battery to Controller Side

[Removal]

[Attachment]

Pull the connector

to remove the

battery.

Attach the

fastener

enclosed in the new

battery to the side

surface of the new

battery.

Join the 2 pieces of the

fastener

, one on the

controller and the other

on the battery, to affix

the battery.

Plug in connector to

absolute battery

connector.