Chapter 3 Operation

POWER CON

PCON-CA/CFA

72

13) Transported load ······Register 4 types of load weights with using the teaching tool, and

choose the number from the registered numbers (0 to 3) that is to be

used.

From the numbers (load weights) registered in this section, the

shortest tact time function calculates the optimum speed and

acceleration/deceleration.

[Refer to the instruction manual of smart teaching tool for how to

register the load weights and shortest tact time.]

Setting

Name

0

Transported Load No.0

1

Transported Load No.1

2

Transported Load No.2

3

Transported Load No.3

14) Stop mode ················Automatic servo OFF is enabled after a certain period from the

completion of positioning for power saving.

A proper period can be selected from three parameters.

Setting

Operation after completion of operation

parameter No.

0

Servo ON not changed

1

Automatic servo OFF after certain period

36

2

Automatic servo OFF after certain period

37

3

Automatic servo OFF after certain period

38

4

Full servo control

5

Full-servo control for a certain time and

then automatically turning servo OFF

36

6

Full-servo control for a certain time and

then automatically turning servo OFF

37

7

Full-servo control for a certain time and

then automatically turning servo OFF

38

 

Caution: y No retaining torque is provided in automatic servo OFF. Pay sufficient

attention to the setting because the actuator may be moved by external

force applied to it.

y

Do not use the automatic servo OFF if the next moving command is relative

distance specification (pitch feed). Failure to follow it may cause position

shift to occur.

y

Do not use the automatic servo OFF in pressing. If used, the pressing force

is lost.

y

Automatic Servo OFF would not function in the operation with teaching

mode of PC software.



15) Vibration suppress No.····· Do not set up.