Pcon-ca/cfa, Power con, Rcb-lb-tg – IAI America PCON-CA User Manual

Page 238: Chapter 9 appendix

Advertising
background image

Chapter 9

Appendix

POWER CON

PCON-CA/CFA

230

3) In case of category 3 or 4

CON-PGA

(or Dummy plug: DP-4)

Connection Cable CB-CON-LB***

Controller

● PCON

ENBOUT

ENBIN

ENB2+

ENB2-

ENB1+

ENB1-

EMGOUT

EMGIN

EMG2+

EMG2-

EMG1+

EMG1-

RCB-LB-TG

Motor

Power

Supply

12

11

10

9

8

7

6

5

4

3

2

1

Solenoid Contactor Solenoid Contactor

Enable SW

Reset SW

Emergency Stop SW

Emergency Stop SW

For Category 4, insert

Reset Switch as shown

in the diagram.

For Category 3, layout

the wiring without

inserting Reset Switch.

For Category 4, make

the connection of A

and B open.

For category 3, make

a short circuit

between A and B.

EMG−

S2

S1

24V

MPO

MPI