Pcon-ca/cfa, Power con – IAI America PCON-CA User Manual

Page 233

Advertising
background image

Chapter 9

Appendix

POWER CON

PCON-CA/CFA

225

Ɣ Upper side (EMG) connector

Ɣ Lower side (ENB) connector

EMG1-

EMG1+

EMG2-

EMG2+

EMGIN

EMGOUT

ENB1-

ENB1+

ENB2-

ENB2+

ENBIN

ENBOUT

EMG1-

EMG1+

EMG2-

EMG2+

EMGIN

EMGOUT

1

6

1

6

Wiring Color

YW

1

2

3

4

5

6

YW

YW

YW

Signal No.

AWG24

ENB1-

ENB1+

ENB2-

ENB2+

ENBIN

ENBOUT

Wiring Color

YW

1

2

3

4

5

6

YW

YW

YW

Signal No.

AWG24

Upper

side

Lower

side

TP Adapter Side View

(3) Connection of dummy plug of TP adapter

When operating the controller with AUTO Mode, make sure to connect the enclosed dummy

plug to TP Connector.

(4) Enable function*

If you are using the enable function, set it to Enable using the controller parameter.

Parameter No.42 Enable function

0 ··· Enable

1 ··· Disable [Default setting at shipment]

* Enable function : It is the function to monitor the status of the signal (safety switch, dead

man’s switch on teaching pendant, etc.) to permit the devices to operate.

Advertising