Pcon-ca/cfa, Power con, 3 connection of pio – IAI America PCON-CA User Manual

Page 67

Advertising
background image

Chapter 2 Wiring

POWER CON

PCON-CA/CFA

59

2.3.3 Connection of PIO

Conduct the connection of I/O to the controller is to be carried out using the dedicated I/O cable.

The cable length is shown in the model code of the controller. Please check the controller

model code. There are 2m for standard, 3m and 5m as an option. Up to 10m I/O cables are

sold separately. [Refer to 1.1.5 How to read the model]

Also, the end of the cable harness to be connected to the host controller (PLC, etc.) is just cut

and no treatment is conducted so the wiring layout can be performed freely.

Model : CB-PAC-PIOƑƑƑ

(ƑƑƑ indicates the cable length L. Example. 020 = 2m)

No.

Cable

Color

Wiring

No.

Cable

Color

Wiring

1A

BR-1

1B

BR-3

2A

RD-1

2B

RD-3

3A

OR-1

3B

OR-3

4A

YW-1

4B

YW-3

5A

GN-1

5B

GN-3

6A

BL-1

6B

BL-3

7A

PL-1

7B

PL-3

8A

GY-1

8B

GY-3

9A

WT-1

9B

WT-3

10A

BK-1

10B

BK-3

11A

BR-2

11B

BR-4

12A

RD-2

12B

RD-4

13A

OR-2

13B

OR-4

14A

YW-2

14B

YW-4

15A

GN-2

15B

GN-4

16A

BL-2

16B

BL-4

17A

PL-2

17B

PL-4

18A

GY-2

18B

GY-4

19A

WT-2

19B

WT-4

20A

BK-2

Flat Cable

٤

A

(Press Welding)

AWG28

20B

BK-4

Flat Cable

٤

B

(Press Welding)

AWG28

For the signal assignment of each wire, refer to the following considering the operation mode.

1) Positioner Mode······························2.1.3 [4] PIO Circuit

2) Pulse Train Control Mode···············2.2.3 [3] PIO Circuit