Pcon-ca/cfa, Power con, Chapter 9 appendix – IAI America PCON-CA User Manual

Page 269

Advertising
background image

Chapter 9

Appendix

POWER CON

PCON-CA/CFA

261

Lead

Minimum

speed

Maximum speed

Maximum

acceleration/

deceleration

Minimum

push force

Maximum

push

force

Rated

push

speed

Actuator

series

Type

Feed

screw

No. of

encoder

pulses

[mm]

Mounting

direction

[mm/s]

[mm/s]

[G]

[N]

[N]

[mm/s]

Horizontal

1.0

24

Vertical

30

(Note) It is the value

when

high-thrust

function is

effective.

1200 (at 50 to 600st)

1155 (at 650st)

1010 (at 700st)

890 (at 750st)

790 (at 800st)

0.5

32

112

Horizontal

(Note) It is the value

when

high-thrust

function is

effective.

980 (at 50 to 550st)

865 (at 600st)

750 (at 650st)

655 (at 700st)

580 (at 750st)

515 (at 800st)

1.0

16

Vertical

20

(Note) It is the value

when

high-thrust

function is

effective.

840 (at 50 to 600st)

750 (at 650st)

655 (at 700st)

580 (at 750st)

515 (at 800st)

0.5

48

168

20

Horizontal

1.0

8

Vertical

10

(Note) It is the value

when

high-thrust

function is

effective.

490 (at 50 to 550st)

430 (at 600st)

375 (at 650st)

325 (at 700st)

290 (at 750st)

255 (at 800st)

0.5

96

336

Horizontal

(Note) It is the value

when

high-thrust

function is

effective.

245 (at 50 to 550st)

215 (at 600st)

185 (at 650st)

160 (at 700st)

145 (at 750st)

125 (at 800st)

1.0

RCP4

(slider

type)

SA7C

Ball

screw

800

4

Vertical

5

(Note) It is the value

when

high-thrust

function is

effective.

210 (at 50 to 600st)

185 (at 650st)

160 (at 700st)

145 (at 750st)

125 (at 800st)

0.5

192

673