Chapter 3 Operation

POWER CON

PCON-CA/CFA

125

(Example) Repetition of ST1 o ST2 o ST1 o

Insert timer 't if necessary.

Ǎ

t : Time required to certainly reach the target position after the position sensing output LS1 or 2 is turned on.

[Example of stop position when the ST* signal is turned OFF by the LS* signal]

If the positioning width is set at a position before the original deceleration start position, the

actuator cannot reach the target position.

 

Caution: (1) If the ST* signal for the position is turned ON after the completion of

positioning, the LS* signal remains ON.

(2) Both the LS* and PEND signals are set to ON in the positioning width zone.

Accordingly, they may be turned ON under operation of the actuator if a large

positioning width is set.

(3) Interlock should be taken so that two or more ST* signals are set to ON

simultaneously. If two or more ST* signals are input simultaneously, they will

be executed according to the following priorities: ST0oST1oST2

(4) LS* signal would not be output if the positioning width is set less than the

minimum resolution.

Start signal

ST1

(PLCoController)

Turned ON after

entering into

positioning width zone

Target Position

Position sensing output

LS1

(ControlleroPLC)

Start signal

ST2

(PLCoController)

Position sensing output

LS2

(ControlleroPLC)

Ǎ

t

Ǎ

t

Ǎ

t

Start signal

ST1

(PLCoController)

Turned ON after

entering into

positioning width zone

Target

Position

Position sensing output

LS1

(ControlleroPLC)

Operation of actuator

Stop before target position

Orignal deceleration

start position

Positioning

width

Deceleration

start

Velocity

Move

distance