238

[4] Reset Circuit

If the “Stop” button on the operation box is pushed during pause, the “Reset” signal sent from

PLC to PCON is turned ON and the remaining moving distance is cancelled. In addition, this

operation releases the pause. (It is because the pause is not required with no remaining

moving distance.)

034

038

OUT3

OUT15

OUT2

IN15

OUT15

RES

HOLDL

Pause

Display

RES

Reset

STOPL

RC Stop

Display

*ALM

* Alarm

Reset

a038

Waiting for Reset

b030

After 200 ms from reset input, the “Pause”

lamp goes off and the “Pause” signal is

turned OFF.

Thus, the reset signal remains ON for 200ms.

Due to no reset complete signal, pause

state is not cancelled until reset

processing is completed.

(Interlock)

Reset input is disabled because alarm

reset is generated while an alarm

occurs.

200ms is

set to

TIM1