Chapter 2 Wiring

POWER CON

PCON-CA/CFA

56

[4] Circuits for Pulse Train Control

Ɣ When Host Unit is Differential System

Caution : Make short-circuit between the host (positioning unit) and the 0V on PIO

connector.

Ɣ When Host Unit is Open Collector System

AK-04 (to be purchased separately) is required for pulse train input.

Caution : 1) Use the same power source for the host open collector input and output,

AK-04.

2) Have the cables as short as possible between the host unit and AK-04.

0V

24V

DC

0V

0V

1
2
3
4

1
2
3
4

PCON

PIO Connector

3A
4A

17B
18B

19B
20B

Host Unit
Positioning Unit

Pulse

Command

0V
0V

PP

/PP
NP
/NP

/PP

PP

NP

/NP

NP

PP

0V

24V

Pulse Converter

AK-04

(to be purchased separately)

PCON

PIO Connector

3A
4A

17B
18B

Host Unit
Positioning Unit

Pulse Command

(Line Driver:

26C31 or equiv.)

PP

/PP

NP

/NP

It is recommended that PP and

/PP and also NP and /NP are

twisted with each other so the

system can be run safely.