Chapter 7 I/O Parameter

POWER CON

PCON-CA/CFA

181

[36] Velocity override (Parameter No.46)

No.

Name

Symbol

Unit

Input Range

Default factory

setting

46 Velocity override

OVRD

%

0 to 100

100

When move commands are issued from the PLC, the moving speed set in the “Velocity” field of

the position table can be overridden by the value set by this parameter.

Actual movement velocity = [Velocity set in the position table] × [setting value in Parameter

No.46]

Example) Value in the “Velocity” field of the position table: 500mm/s

Setting in Parameter No.46 20%

In this case, the actual movement speed becomes 100mm/s.

The minimum setting unit is 1% and the input range is 1 to 100%.

(Note) This parameter is ignored for move commands from a teaching tool such as PC

software.

[37] PIO jog velocity 2 (Parameter No.47)

No.

Name

Symbol

Unit

Input Range

Default factory

setting

47 PIO Jog Speed 2

IOV2

mm/s

(deg/s)

1 to Actuator’s max.

speed

100

This is the setting of JOG operation speed when 1 is set in the JOG speed / inching distance

switchover signal JVEL for Field Network Type.

Set the appropriate value considering how the system is to be used.

Note 1 The maximum speed is limited to 250mm/s.

[38] PIO inch distance, PIO inch distance 2 (Parameter No.48, No.49)

No.

Name

Symbol

Unit

Input Range

Default factory

setting

48 PIO inch distance

IOID

mm

0.01 to 1.00

0.1

49

PIO inch distance 2

IOD2

mm

0.01 to 1.00

0.1

When the selected PIO pattern is “1” (Teaching Mode), Parameter No.48 defines the inching

distance to be applied when inching input commands are received from the PLC. Parameter

No.49 defines the inching distance when 1 is set in the JOG speed / inching distance

switchover signal JVEL for Field Network Type.

The maximum allowable value is 1 mm.

[39] Load output judgment time period (Parameter No.50)

No.

Name

Symbol

Unit

Input Range

Default factory

setting

50 Load output judgment time period LDWT

msec

0 to 9999

255

This parameter defines the time taken to judging whether torque level status signal (TRQS) is

ON.

If the command torque exceeds the value set in “Threshold” of position data for the time set by

this parameter during pressing operation, torque level status signal (TRQS) is turned ON.

Refer to 3.2.4 [4] or 3.2.5 [3] Pressing Operation for the details of the pressing operation.