Pcon-ca/cfa, Power con, Chapter 9 appendix – IAI America PCON-CA User Manual

Page 267

Advertising
background image

Chapter 9

Appendix

POWER CON

PCON-CA/CFA

259

Lead

Minimum

speed

Maximum speed

Maximum

acceleration/

deceleration

Minimum

push force

Maximum

push

force

Rated

push

speed

Actuator

series

Type

Feed

screw

No. of

encoder

pulses

[mm]

Mounting

direction

[mm/s]

[mm/s]

[G]

[N]

[N]

[mm/s]

Horizontal

(Note) It is the value

when

high-thrust

function is

effective.

1440 (at 50 to 500st)

1225 (at 550st)

1045 (at 600st)

900 (at 650st)

785 (at 700st)

690 (at 750st)

610 (at 800st)

1.0

20

Vertical

25

(Note) It is the value

when

high-thrust

function is

effective.

1280 (at 50 to 500st)

1225 (at 550st)

1045 (at 600st)

900 (at 650st)

785 (at 700st)

690 (at 750st)

610 (at 800st)

1.0

16

56

20

Horizontal

1.0

12

Vertical

15

(Note) It is the value

when

high-thrust

function is

effective.

900 (at 50 to 450st)

795 (at 500st)

665 (at 550st)

570 (at 600st)

490 (at 650st)

425 (at 700st)

375 (at 750st)

330(at 800st)

0.5

26

93

12

Horizontal

1.0

6

Vertical

7.5

(Note) It is the value

when

high-thrust

function is

effective.

450 (at 50 to 450st)

395 (at 500st)

335 (at 550st)

285 (at 600st)

245 (at 650st)

215 (at 700st)

185 (at 750st)

165 (at 800st)

0.5

53

185

6

Horizontal

1.0

RCP4

(slider

type)

SA5C

Ball

screw

800

3

Vertical

3.75

(Note) It is the value

when

high-thrust

function is

effective.

225 (at 50 to 450st)

195 (at 500st)

165 (at 550st)

140 (at 600st)

120 (at 650st)

105 (at 700st)

90 (at 750st)

80 (at 800st)

0.5

106

370

3

Advertising