Pcon-ca/cfa, Power con – IAI America PCON-CA User Manual

Page 198

Advertising
background image

Chapter 7 I/O Parameter

POWER CON

PCON-CA/CFA

190

[73] IP address (Parameter No.140)

No.

Name

Symbol

Unit

Input Range

Default factory

setting

140 IP address

IPAD

mm

0.0.0.0 to

255.255.255.255

192.168.0.1

It is the parameter dedicated for Field Network (EtherNet/IP).

[Refer to Ether Net/IP Instruction Manual (ME0278) provided separately.]

[74] Subnet mask (Parameter No.141)

No.

Name

Symbol

Unit

Input Range

Default factory

setting

141 Subnet mask

SNMK

0.0.0.0 to

255.255.255.255

255.255.255.0

It is the parameter dedicated for Field Network (EtherNet/IP).

[Refer to Ether Net/IP Instruction Manual (ME0278) provided separately.]

[75] Default gateway (Parameter No.142)

No.

Name

Symbol

Unit

Input Range

Default factory

setting

142 Default gateway

DFGW

0.0.0.0 to

255.255.255.255

0.0.0.0

It is the parameter dedicated for Field Network (EtherNet/IP).

[Refer to Ether Net/IP Instruction Manual (ME0278) provided separately.]

[76] Overload level ratio (Parameter No.143)

No.

Name

Symbol

Unit

Input Range

Default factory

setting

143 Overload level ratio

OLWL

%

50 to 100

100

Do not change the default value.

[77] Gain scheduling upper limit multiplying ratio (Parameter No.144)

No.

Name

Symbol

Unit

Input Range

Default factory

setting

144 Gain scheduling upper limit

multiplying ratio

GSUL

%

0 to 1023

0(Disabling)

Gain scheduling is the function to change the gain in accordance with the operation speed.

This parameter shows the multiplying rate of the upper limit of the changeable gain.

With the set multiplying rate, the values for GS Velocity Loop Proportional Gain (Parameter

No.145) and GS Velocity Loop Integrated Gain (Parameter No.146) are changed.

Set Value

Description

100 or less

Gain scheduling disabled

101 to 1023 Gain scheduling enabled

(Recommended value 300)