Chapter 7 I/O Parameter

POWER CON

PCON-CA/CFA

182

[40] Torque inspected range (Parameter No.51)

No.

Name

Symbol

Unit

Input Range

Default factory

setting

51 Torque inspected range

TRQZ

0 : Enabling

1 : Disabling

0

The load output (LOAD) turns ON when it exceeds the current [%] set as the position table

threshold in the range (check range) set with Zone +/Zone – in the position table during the

pressing operation.

[41] Default acceleration/deceleration mode (Parameter No.52)

No.

Name

Symbol

Unit

Input Range

Default factory

setting

52 Default acceleration/deceleration

mode

CTLF

0 to 2

0 (Trapezoid)

When a target position is written to an unregistered position table, this value is automatically set

as the “Acceleration/deceleration mode” of the applicable position number.

Set Value

Description

0

Trapezoid

1

S-motion

2

Primary delay filter

[42] Default stop mode (Parameter No.53)

No.

Name

Symbol

Unit

Input Range

Default factory

setting

53 Default stop mode

CTLF

0 to 7

0 (Does not use)

This parameter defines the power-saving function.

[Refer to Chapter 5 Power-saving Function.]

[43] Position-command primary filter time constant (Parameter No.55)

No.

Name

Symbol

Unit

Input Range

Default factory

setting

55 Position-command primary filter

time constant

PLPF

msec

0.0 to 100.0

0

Use this in the case to set the value in “Acceleration/Deceleration” box in the position table to 2

“1-step delay filter”, or in the case that there is no acceleration/deceleration function the host

controller in Pulse Train Control Mode.

The primary delay filter is disabled if “0” is set.

The greater the setting value is, the longer the delay is and the slower the

acceleration/deceleration is. The impact at the acceleration and deceleration will be eased, but

the takt time will become longer.

Refer to 3.3.5 [1] Position command primary filter time constant for the details of Pulse Train

Control Mode.

Velocity

Time