Pcon-ca/cfa, Power con – IAI America PCON-CA User Manual

Page 92

Advertising
background image

Chapter 3 Operation

POWER CON

PCON-CA/CFA

84

{

: ON z: OFF

*ALM ALM8

(PM8)

ALM4

(PM4)

ALM2

(PM2)

ALM1

(PM1) Binary Code

Description: Alarm code is shown in ( ).

z

{

z

z

z

8

Actual speed excessive (0C0)

z

{

z

z

{

9

Regenerative electric discharge circuit error (0C7)

Overcurrent (0C8)

Overvoltage (0C9)

Overheat (0CA)

Control power source voltage error (0CC)

Drop in control supply voltage (0CE)

Drive source error (0D4)

z

{

z

{

{

11

Command counter overflow (0A4)

Command counter overflow in Incomplete home

return (0D5)

Deviation Overflow (0D8)

Software stroke limit exceeded (0D9)

Pressing motion range over error (0DC)

z

{

{

z

z

12

Servo error (0C1)

Motor power source voltage excessive (0D2)

Overload (0E0)

z

{

{

z

{

13

Encoder receipt error (0E5)

A- and B-phase Wire Breaking (0E8)

Absolute encoder error detection 1 (0ED)

Absolute encoder error detection 2 (0EE)

Absolute encoder error detection 3 (0EF)

z

{

{

{

z

14

CPU Error (0FA)

Logic Error (0FC)

z

{

{

{

{

15

Nonvolatile memory write verify error (0F5)

Nonvolatile memory write timeout (0F6)

Nonvolatile memory data destroyed (0F8)

(Note) *ALM Signal is an active low signal. It is ON when the power is applied to the controller, and

turns OFF when the signal is output.

Advertising