Pcon-ca/cfa, Power con, 6] default velocity (parameter no.8) – IAI America PCON-CA User Manual

Page 179

Advertising
background image

Chapter 7 I/O Parameter

POWER CON

PCON-CA/CFA

171

[6] Default velocity (Parameter No.8)

No.

Name

Symbol

Unit

Input Range

Default factory

setting

8 Default velocity

VCMD

mm/s

(deg/s)

1 to Actuator’s

max. verocity

Rated actuator

speed

The factory setting is the rated velocity of the actuator.

When a target position is set in an unregistered position table, the setting in this parameter is

automatically written in the applicable position number.

It is convenient to set the velocity often used.

[7] Default acceleration/deceleration (Parameter No.9)

No.

Name

Symbol

Unit

Input Range

Default factory

setting

9 Default acceleration/deceleration

ACMD

G

0.01 to actuator's

max. acceleration/

deceleration

Rated actuator's

acceleration/

deceleration

The factory setting is the rated acceleration/deceleration of the actuator.

When a target position is set in an unregistered position table, the setting in this parameter is

automatically written in the applicable position number.

It is convenient to set the acceleration/deceleration often used.

[8] Default positioning width (in-position) (Parameter No.10)

No.

Name

Symbol

Unit

Input Range

Default factory

setting

10 Default positioning width

INP

mm

(deg)

0.01

(Note)

to 999.99

0.10

When a target position is set in an unregistered position table, the setting in this parameter is

automatically written in the applicable position number. When the remaining moving distance

enters into this width, the positioning complete signal PEND/INP is output.

It is convenient to set the positioning width often used.

(Note) For RCP4 Series actuators, it is down to the minimum positioning width

(L = Lead length/800).

[9] Current-limiting value at standstill during positioning (Parameter No.12)

No.

Name

Symbol

Unit

Input Range

Default factory

setting

12 Current-limiting value at standstill

during positioning

SPOW

%

1 to 70

In accordance

with actuator

When the value is increased, the stop holding torque is increased.

Even though it is generally unnecessary to change this setting, setting the value larger is

necessary in the case a large external force is applied during stop. Please contact IAI.