216

Alarm

Code Alarm Level

Alarm Name

Cause/Treatment

0F5

Operation

release

Nonvolatile memory write

verify error

It is verified at the data writing process to the non-volatile

memory that the data inside the memory and the data to be

written are matched. There was a mismatch detected in this

process.

Cause

: Faulty nonvolatile memory.

Treatment : When the error is caused even when the power

is re-input, please contact IAI.

0F6

Nonvolatile memory write

timeout

There is no response in the specified time duration during the

data writing to the non-volatile memory.

Cause

: Faulty nonvolatile memory.

Treatment : When the error is caused even when the power

is re-input, please contact IAI.

0F8

Nonvolatile memory data

destroyed

Abnormal data was detected during the nonvolatile memory

check after starting.

Cause

: Faulty nonvolatile memory.

Treatment : When the error is caused even when the power

is re-input, please contact IAI.

0FA

CPU error

The CPU operation is not normal.

Cause

: 1) Faulty CPU.

2) Malfunction due to noise.

Treatment : When the error is caused even when the power

is re-input, please contact IAI.

0FC

Cold start

Logic error

(Faulty component)

The controller is not operating properly.

Cause

: 1) Malfunction due to the effect of noise, etc.

2) Malfunction of peripheral circuit components.

Treatment : Turn the power OFF and reboot.

If the error occurs again, check for presence of

noise.

If a spare controller is available, replace the

problem controller with the spare controller. A

recurring error with the spare controller suggests

presence of noise.

If the cause cannot be identified, please contact

IAI.

100 to

1FF

Message Alarm on teaching tool

[Refer to the Instruction Manual of teaching tool.]

200 to

2FF

Operation

release

Alarm on teaching tool

[Refer to the Instruction Manual of teaching tool.]

300 to

3FF

Cold start Alarm on teaching tool

[Refer to the Instruction Manual of teaching tool.]

Advertising