Chapter 2 Wiring

POWER CON

PCON-CA/CFA

41

(3) List of PIO Signals

The table below lists the functions of PIO signals. Refer to the section shown in Relevant

Sections for the details of the control of each signal.

Category

Signal

Abbreviation

Signal Name

Function Description

Relevant

Sections

CSTR

PTP strobe

(Start signal)

The actuator will start to move to the position set by the

command position number.

3.2.4

PC1 to

PC256

Command position

number

Input (in binary) a number of the position that is desired to move. 3.2.4

BKRL

Brake forcible release The brake will forcibly be released.

3.2.3

RMOD

Operation mode

changeover

The operating mode is selectable when the MODE switch of the

controller is set to AUTO.

(The setting is AUTO when signal is OFF, and MANU when ON.)

3.2.3

*STP

Pause

When this signal turns OFF while the actuator is moving, the

actuator will decelerate to stop. The remaining

movement is in a hold while the actuator is stopped and will

resume when the signal turns back ON.

3.2.4

3.2.5

3.2.6

RES

Reset

An alarm will be reset when this signal is turned ON. Also, when

it is turned ON in the pause mode (*STP is turned OFF), the

remaining movement amount can be cancelled.

3.2.3

3.2.4

3.2.5

3.2.6

SON

Servo ON

The servo remains ON while this signal is ON, or OFF while this

signal is OFF.

3.2.4

HOME

Home return

The controller will perform home return operation when this

signal is turned ON.

3.2.3

MODE

Teaching mode

The operating mode will change to the teaching mode when this

signal is turned ON. The mode will not be switched over unless

CSTR, JOG+ and JOG- are all OFF and the actuator operation is

stopped.

3.2.4

JISL

Jog/inching selector

Jog Operation can be performed with JOG+ and JOG- while this

signal is OFF.

Inching Operation is performed with JOG+ and JOG- when it is

ON.

3.2.4

JOG +

JOG -

Jog

Jog Operation is performed to positive direction by detecting ON

edge of JOG+ signal and to negative direction by JOG- signal

while JISL signal is OFF.

The actuator will decelerate and stop if OFF edge is detected

while in each Operation.

Inching Operation is performed while JISL signal is ON.

3.2.4

PWRT

Current Position Write

When the write position is specified in the teaching mode and

this signal has remained ON for 26msec or longer, the controller

will write the current position in the specified position field.

3.2.4

Input

ST0 to ST6 Start Signal

The actuator moves to the commanded position with this signal

ON during the solenoid valve mode.

3.2.5

3.2.6


Signal with “*” expresses the signal of active low. In the controller, the process is held when the input signal is turned OFF.