Chapter 3 Operation

POWER CON

PCON-CA/CFA

119

3.2.6 Direct Position Specification (Solenoid Valve Mode 2) = Operation of PIO

Pattern 5

The start signal is provided for every position number. Only turning ON the relevant input signal

according to the table shown below allows the operation based on the data in the target

position number to be performed. The operation mode is called the solenoid valve mode

because solenoid valves can directly drive air cylinders. At invasion of the actuator into the

positioning width set for each position, the output signal is turned ON in the operation of any

position number or manual operation of the actuator in servo OFF status as if a sensor were

installed.

Positioning and speed change during operation are possible. Their control methods are the

same as those of other patterns.

 

Caution: This pattern does not allow pressing and pitch feed.

[1] Home return (ST0, HEND)

The I/O of PIO varies as shown in the table below depending on the position number before

home return.

Position No.

Input

Output

0

ST0

LS0

1

ST1 Ÿ JOG+

LS1

2

ST2 Ÿ Invalid

LS2 Ÿ Invalid

Before home return, start signal ST0 works as JOG- moving to the home return direction while

it is set to ON and ST1 works as JOG+ while it is set to ON. By using this function, move the

actuator to a position at which home return can be done safely. The speed of ST1 is the home

return speed.

After the home return is fully prepared, turn the ST0 signal ON to start the home return. At the

completion of the home return, home return complete signal HEND is turned ON. Turn the ST0

signal OFF if HEND is turned ON. HEND remains ON unless the home is lost due to

occurrence of an alarm.

If a certain home positioning is required, Set “Position” of position No.0 to 0 mm and the ST0

signal is not changed by the HEND signal to remain ON. After the home return is completed,

positioning is provided for position No.0. [Refer to 3.2.6 [3] Positioning.]

 

Warning: (1) Use this pattern with Parameter No.27 “Move command type” set to “0”

(factory setting). When Parameter No.27 is set to “1”, the home return is

started as soon as the ST0 signal is turned ON and the operation cannot be

stopped even if ST0 is turned OFF.

(2) If “Position” in position No.0 is set to other than 0mm, the operation is

continued without change to provide positioning after home return.

Home return signal

ST0

(PLCoController)

If a certain precision is required. Set

"Position" of position No.0 to 0 mm and

ST0 is not chaged by HEND to remain ON.

Homing Completion Signal

HEND

(ControlleroPLC)