Chapter 5 Power-saving Function (Automatic Servo-of

f and Full Servo Functions)

POWER CON

PCON-CA/CFA

152

(1) Setting of periods taken until automatic servo OFF

Three periods from completion of positioning to automatic servo OFF can be set in the

following parameters in seconds [sec].

Parameter No.

Description

36

Auto Servo Motor OFF Delay Time 1 (Unit: sec)

37

Auto Servo Motor OFF Delay Time 2 (Unit: sec)

38

Auto Servo Motor OFF Delay Time 3 (Unit: sec)

(2) Set of power-saving mode

Select a proper power-saving mode from the conditions below. Set the corresponding value

in the stop mode or parameter No.53 of the position table.

Set Value

Operation after completion of positioning

0

Servo ON not changed

1

Automatic servo off in a certain time (set in Parameter No.36)

2

Automatic servo off in a certain time (set in Parameter No.37)

3

Automatic servo off in a certain time (set in Parameter No.38

4

Full Servo Control

5

Full-servo control for a certain time (value set in Parameter

No.36) and then automatically turning servo OFF

6

Full-servo control for a certain time (value set in Parameter

No.37) and then automatically turning servo OFF

7

Full-servo control for a certain time (value set in Parameter

No.38) and then automatically turning servo OFF

(3) Status of positioning complete signal in selection of automatic servo OFF

Automatic servo OFF causes the actuator to be in other than the positioning complete state

due to the servo OFF. Positioning complete signal (PEND) is turned OFF. Changing the

PEND signal to the in-position signal judging whether the actuator is stopped within the

positioning width zone instead of the positioning complete signal allows PEND not to be

turned OFF during servo OFF.

This setting is reflected on complete position numbers PM1 to PM** in PIO patterns 0 to 3

confirming the positioning complete position No. or current position numbers PE* in PIO

patterns 4.

Define the setting in Parameter No.39.

Signal outputs during automatic servo OFF

Value set in

Parameter No.39

Content of PEND

signal

PEND

PM1 to PM**

PE**

0

Positioning

Completion Signal

OFF

OFF

OFF

1

In-position Signal

ON

ON

ON

(Note) The SV on the front panel blinks green during the automatic servo OFF.